NEXURA

Features and Benefits

A floor standing air conditioner with a modern design that blends in with your home’s decor. It is quiet, discrete and features state-of-the-art heating technology.


Available Reverse Cycle (Heating & Cooling)


Technical Specification
INDOOR UNIT  FVXG25K2V1B FVXG35K2V1B FVXG50K2V1B
OUTDOOR UNIT  RXG25L2V1B RXG35L2V1B RXG50L2V1B
Rated Capacity Cool (kW) 2.5 3.5 4.8
Heat (kW) 3.4 4.5 5.8
Capacity Range Cool (kW) 1.3-3.0 1.4-3.8 1.7-5.6
Heat (kW) 1.3-4.5 1.4-5.0 1.7-8.1
Indoor Airflow Rate (Hi) Cool (l/s) 148 151 176
Heat (l/s) 165 170 203
Indoor Fan Speeds C/H 5 steps, quiet and automatic
Energy Label/Star Ratings Cool 5 2.5 1.5
Heat 4 2.5 2.5
Front Panel Colour   White
Power Supply   1 phase, 220-240V, 50Hz
Power Input (Rated) Cool (kW) 0.54 0.94 1.43
Heat (kW) 0.76 1.21 1.57
E.E.R / C.O.P Cool/Heat 4.63/4.47 3.72/3.72 3.36/3.69
A.E.E.R / A.C.O.P Cool/Heat 4.57/4.43 3.69/3.70 3.22/3.57
Dimensions (HxWxD) Indoor (mm) 600x950x215 600x950x215 600x950x215
Outdoor (mm) 550x765x285 550x765x285 735x825x300
Weight Indoor (kg) 22
Outdoor (kg) 35 35 48
Compressor Type   Hermetically sealed swing type
Refrigerant Type   R410A
Max Pipe Length (m) 20 20 30
Max Level Difference (m) 15 15 20
Pipe Sizes Liquid (mm) 6.4
Gas (mm) 9.5 9.5 12.7
Outdoor Operative Range (Outdoor Temp) Cool (CDB)  10 to 46
Heat (CWB) -15 to 18
Indoor Sound Level (H/SL) Cool (dBA) 38/23 39/24 44/32
Heat (dBA) 39/22 40/23 46/30
Outdoor Sound Level (H/SL) Cool (dBA) 46/43 48/44 48/44
Heat (dBA) 47/44 48/45 48/45
Outdoor EPA Sound Power Level (H) Cool (dBA) 63
Heat (dBA) 63
Download Technical Specifications